QR link for Multi-criteria Site Selection for Fire Services: the Interaction with Analytic Hierarchy Process and Geographic Information Systems : Volume 10, Issue 10 (08/10/2010)
Add to Book Shelf
Flag as Inappropriate
Email this Book

Multi-criteria Site Selection for Fire Services: the Interaction with Analytic Hierarchy Process and Geographic Information Systems : Volume 10, Issue 10 (08/10/2010)

By Erden, T.

Click here to view

Book Id: WPLBN0003987475
Format Type: PDF Article :
File Size: Pages 8
Reproduction Date: 2015

Title: Multi-criteria Site Selection for Fire Services: the Interaction with Analytic Hierarchy Process and Geographic Information Systems : Volume 10, Issue 10 (08/10/2010)  
Author: Erden, T.
Volume: Vol. 10, Issue 10
Language: English
Subject: Science, Natural, Hazards
Collections: Periodicals: Journal and Magazine Collection, Copernicus GmbH
Historic
Publication Date:
2010
Publisher: Copernicus Gmbh, Göttingen, Germany
Member Page: Copernicus Publications

Citation

APA MLA Chicago

Erden, T., & Coşkun, M. Z. (2010). Multi-criteria Site Selection for Fire Services: the Interaction with Analytic Hierarchy Process and Geographic Information Systems : Volume 10, Issue 10 (08/10/2010). Retrieved from http://cn.ebooklibrary.org/


Description
Description: Istanbul Technical University, Geomatics Engineering Department, 34469, Maslak Istanbul, Turkey. This study combines AHP and GIS to provide decision makers with a model to ensure optimal site location(s) for fire stations selected. The roles of AHP and GIS in determining optimal locations are explained, criteria for site selection are outlined, and case study results for finding the optimal fire station locations in Istanbul, Turkey are included. The city of Istanbul has about 13 million residents and is the largest and most populated city in Turkey. The rapid and constant growth of Istanbul has resulted in the increased number of fire related cases. Fire incidents tend to increase year by year in parallel with city expansion, population and hazardous material facilities. Istanbul has seen a rise in reported fire incidents from 12 769 in 1994 to 30 089 in 2009 according to the interim report of Istanbul Metropolitan Municipality Department of Fire Brigade. The average response time was approximately 7 min 3 s in 2009. The goal of this study is to propose optimal sites for new fire station creation to allow the Fire Brigade in Istanbul to reduce the average response time to 5 min or less. After determining the necessity of suggesting additional fire stations, the following steps are taken into account: six criteria are considered in this analysis. They are: High Population Density (HPD); Proximity to Main Roads (PMR); Distance from Existing Fire Stations (DEF); Distance from Hazardous Material Facilities (DHM); Wooden Building Density (WBD); and Distance from the Areas Subjected to Earthquake Risk (DER). DHM criterion, with the weight of 40%, is the most important criterion in this analysis. The remaining criteria have a weight range from 9% to 16%. Moreover, the following steps are performed: representation of criterion map layers in GIS environment; classification of raster datasets; calculating the result raster map (suitability map for potential fire stations); and offering a model that supports decision makers in selecting fire station sites. The existing 35 fire stations are used and 17 fire stations are newly suggested in the study area.

Summary
Multi-criteria site selection for fire services: the interaction with analytic hierarchy process and geographic information systems

Excerpt
Karaman, H., Scedilahina, M., Elnashaib, A. S., et al.: Earthquake Loss Assessment Features of Maeviz-Istanbul (HAZTURK), J. Earthq. Eng., 12, 175–186, 2008.; Eldrandaly, K., Eldin, N., and Sui, D.: A COM-based Spatial Decision Support System for Industrial Site Selection, Journal of Geographic Information and Decision Analysis, 7(2), 72–92, 2003.; Erden, T.: Fire Brigade Site Selection Based on Geographic Information Systems and Analytic Hierarchy Process: Case Study of Istanbul, Ph.D. dissertation, ITU Institute of Science and Technology, Istanbul, Turkey, 2009.; Erdik, M., Aydinoglu, N., Fahjan, Y., et al.: Earthquake Risk Assessment for Istanbul Metropolitan Area, Earthquake Engineering and Engineering Vibration, 2(1), 1–23, 2003.; Ertugrul, I. and Karakaşoğlu, N.: Comparison of Fuzzy AHP and Fuzzy TOPSIS Methods for Facility Location Selection, Int. J. Adv. Manuf. Tech., 39, 783–795, 2008.; Gay, W. and Siegel, A.: Fire Station Location Analysis: A Comprehensive Planning Approach, ICMA: MIS Report, 1–17, 1987.; Guigin, W., Li, Q., Guoxue, L., and Lüjun, C.: Landfill Site Selection Using Spatial Information Technologies and AHP: A Case Study in Beijing, China, J. Environ. Manage., 90, 2414–2421, 2009.; Jankowski, P.: Integrating Geographic Information Systems and Multicriteria Decision Making Methods, Int. J. Geogr. Inf. Syst., 9(3), 251–273, 1995.; Habibi, K., Lotfi, S., and Koohsari, M. J.: Spatial Analysis of Urban Fire Station Locations by Integrating AHP Model and IO Logic Using GIS (A Case Study of Zone 6 of Tehran), J. Appl. Sci., 8(19), 3302–3315, 2008.; IMM: Critical Risk Areas and Station Locations,  Vol. 7,  Istanbul Metropolitan Municipality The study of Fire Safety and Protection, ITU, Istanbul, Turkey, 1989.; IMM: Interim Report, Department of Fire Brigade, en-US/Pages/statistics.aspx>http://www.ibb.gov.tr/sites/itfaiye/en-US/Pages/statistics.aspx (last access: 23 February 2010, 2009 (in Turkish).; JICA and IMM: The Study on a Disaster Prevention/ Mitigation Basic Plan in Istanbul Including Microzonation in the Republic of Turkey, Final Report, Vol. 5, Istanbul, Turkey, 2002.; Johnston, J.: The Cost Effectiveness of Fire Station Siting and the Impact on Emergency Response, An Applied Research Project, National Fire Academy, 1999.; Jun, C.: Design of an Intelligent Geographic Information System for Multicriteria Site Analysis, URISA Journal, 12(3), 5–17, 2000.; Kontos, T. D., Komilis, D. P., and Halvadakis, C. P.: Siting MSW Landfills With a Spatial Multiple Criteria Analysis Methodology, Waste Manage., 25, 818–832, 2005.; Miller, G. A.: The Magical Number Seven, Plus or Minus Two: Some Limits on Our Capacity for Processing Information, Psychological Review, 101(2), 343–352, 1956.; NFPA 1710: Standard for the Organization and Deployment of Fire Suppression Operations, Emergency Medical Operations, and Special Operations to the Public by Career Fire Departments, National Fire Protection Association, 2001.; Ozcan, H.: Urban Sprawl Prediction in Using Neural Networks, M.Sc. thesis, ITU Institute of Science and Technology. Istanbul, Turkey, 2008.; Petersen, C. E.: 1998 AMES Fire Department Response Time Study. Executive Development, An Applied Research Project,National Fire Academy as part of the Executive Fire Officer Program, submitted, 1998.; Reveshti, M. A. and Heidari, A.: Site Selection Study for Fire Extinguisher Stations Using Network Analysis and AHP Model: A Case Study of City of Zanjan, MapAsia 2007, Kuala Lumpur, Malaysia, 2007.; Saaty, T. L.: The Analytic Hierarchy Process, New York, McGraw-Hill, 1980.; Saaty, T. L.: Group Decision Making and AHP, in: the Analytical Hierarchy Process: Applications and Studies, edited by: Golden, B. L., Wasil, E. A., and Harker, P. T., Berlin: Springer, 59–71, 1989.; Sener, B., Suzen B. L., and Doyuran V.: Landfill Site Selection by Using Geographi

 
 